MISCELLANEOUS DEPARTMENT OF DEFENSE
PROJECTS

FY03 AJJY033106A AEF FOL Aircraft Maintenance Hangar, Andersen Air Force Base, Guam.
The Aircraft Maintenance Hangar is a new hangar building consisting of a maintenance area to service either one B-52 or two B-2 airplanes within this facility. Scope: Project fire protection engineer responsible for building and life safety consultation, and design of fire protection systems, which include High-Expansion foam system, wet pipe fire sprinkler systems, and fire alarm system.

FY05 MCON P-451, Kilo Wharf Improvements, Guam.
M.I. Design and CQC FPE for wharf fire protection and dock operations improvements, including fire pumps, fire sprinklers, and fire alarm systems.

Hangar 1104, Osan Air Base, South Korea.
Served as fire protection engineering consultant. This project will provide a fire protection systems in accordance with ETL 02-15 for Hangar 1104, to include overhead wet pipe sprinkler system for hangar bay with low level high-expansion foam system. The hangar currently houses F-16 or A-10 type aircraft and will be classified as a Group II hangar. The fire protection system shall be supplied by a fire pump house located near the hangar.

Fire Protection for Hangars 1142 and 1151, Osan Air Base, South Korea.
Project fire protection engineer. This project provides fire protection systems for Hangars 1142 and 1151. The system shall be supplied by a single fire pump house located between the two hangars. The two hangars are used primarily to store C-12 aircraft. The C-12 is a twin engine aircraft made by Beachcraft. While the hangar falls within the NFPA 409 definition of a Group III hangar, the aircraft is not comparable to the types requiring only wet pipe sprinkler protection in accordance with ETL 02-15, A3.1.3.1.1.4. Also, the aircraft may be serviced and stored fully fueled. This requires a wet pipe overhead sprinkler system and low level, high expansion foam.

Fire Protection Hangar 2127, Kwanju Air Base,
South Korea
.
This project will provide a fire protection systems in accordance with ETL 02-15 for Hangar 2127. The hangar currently houses F-15 and F-16 aircraft and will be classified as a Group II hangar. Hangar is provided wet pipe overhead sprinkler system and low level, high expansion foam. All adjacent spaces to the hangar shall be provided with preaction sprinkler protection.

Seal Team Training & Support Facility, NAVSTA Pearl Harbor, Hawaii.
Design of wet pipe and fire alarm systems for new 15,000 square foot shop and training facility.

 

 

 

test

MCON P-203 Maintenance Hangar,
Andersen AFB, Guam.

Design of foam (AFFF) fire suppression systems, wet pipe sprinkler systems, fire alarm and detection systems, a multiple fire pump installation, water storage tanks for new aircraft hangar.

Fire Protection VC-135 - Aircraft Maintenance Hangar, Hickam AFB, Hawaii.
Design of foam (AFFF) fire suppression systems, wet pipe sprinkler systems, fire alarm and detection systems, a multiple fire pump installation, water storage tanks for existing fuel systems maintenance aircraft hangar.

Essential Maintenance Facilities,
Clark Air Base, Philippines.

Design of foam (AFFF) fire suppression systems, wet pipe sprinkler systems, fire alarm and detection systems and a multiple fire pump installation for new and existing aircraft hangars. Performed Building and Life Safety Analysis for Architect.

Avionics/Weapons Release, Hawaii Air National Guard, Hickam AFB, Hawaii.
Design of preaction sprinkler system and fire alarm & detection system.

Install Fire Protection System, Building 112, NAVCAMS WESTPAC, Guam.
Design of automatic preaction, wet pipe and carbon dioxide systems for existing 40,000 square feet communications facility.

Range Operations, Pacific Missile Range Facility, Barking Sands, Kauai, Hawaii.
Design of Halon 1301, fire alarm, detection and sprinkler systems for new electronics facility.

Special Intelligence Facility, Schofield
Barracks, Hawaii.

Design of total flooding Halon 1301 gaseous fire extinguishing system and automatic sprinkler system.

Missile Maintenance Facility, Naval Magazine, West Loch, Pearl Harbor, Hawaii.
Design of preaction sprinkler and fire pump systems.